Skip to content
Project consultation and site visits across Iran
AISI 316 tension cable system

316 stainless steel cable railingOpen views with tension designed for project conditions

Cable railing combines stainless steel wire rope, posts and adjustable fittings for open views and a light appearance. Cable diameter, post spacing, tension and anchorage must be selected for the supporting structure and safety requirements of each project.

Cable strength
According to project specifications
Minimum cable breaking resistance
Stainless steel grade
AISI 316 Marine
Selected for site exposure
Fitting fabrication
CNC machining
Dimensions and tolerances to drawing
Visual openness
Open views, slender lines
Depends on cable and post layout
Cable railing with a timber handrail on an interior staircase
Architectural application
Villa project, Mosha Plain, Damavand
Cable railing
Architectural applications

Cable railing applications in architecture

Cable railing can preserve daylight and airflow on stairs, terraces and roofs. Suitability depends on architectural constraints, loads, access by children and local requirements.

Horizontal and vertical configurations

Duplex and floating staircases

Slender cables can preserve staircase views and daylight. Review infill spacing, the handrail and potential climbing by children alongside the architectural design.

Spans to project design

Exposed terraces and balconies

An open linear appearance that allows airflow, with posts, cables and anchors designed for actual site loads and conditions.

Allows airflow

Roof gardens

On roof gardens, check the weight of posts and anchors, waterproofing at fixings and cleaning access. Spaces between cables allow air and water to pass.

Check complete system weight

Outdoor villa pool surrounds

Near pools, select the stainless grade and cleaning method for chloride and moisture exposure. Suitability as a pool barrier and the risk of children climbing the infill require a separate safety assessment.

Grade selection and maintenance
System components

Structural components of the Aris cable system

Machining quality, thread and cable compatibility, and adjustment access guide fitting selection. Stable tension depends on the complete design, installation and maintenance process.

Stainless wire rope construction for cable railing
Cable construction
4–8 mm diameter

Stainless cable matched to the system

Cable diameter and construction, such as 7×19, must suit the terminals and anchorage method. Check breaking strength and deformation against manufacturer documentation and system calculations.

Cable tension adjustment fitting at a railing post
Tension adjustment
Recessed and concealed

Adjustable in-post tensioner

Fully threaded adjustment screws are concealed inside the hollow post section, keeping exposed threads away from view and hand contact.

Cable railing post and structural connection
Structural post
40×40 box section or 51 mm tube

Reinforced laser-cut posts

Post sections, base-plate thickness and structural connections are selected for applied loads and combined cable tension. A single fixed set of dimensions does not suit every project.

Cable terminals and end connection components
End connection
Cold hydraulic swaging

Pin terminal and protective bushing

Terminals and bushings must match the cable diameter and construction. Tools, dies and swaging methods follow the manufacturer’s instructions, with quality checks on the finished connection.

Technical system comparison

Comparison: tension cable railing and glass railing

Choosing between cable and glass railing is a structural decision. Compare environmental exposure, cost and performance below.

CriterionCable railingGlass railingSelection note
Wind loadingAirflow between cablesWind transferred to fixingsCheck loads and anchorage
MaintenanceCleaning and tension checksSurface and fixing checksAllow service access
System weightPosts, cables and handrailGlass and supporting fixingsCheck supporting structure
Installation timeCable and fitting quantitiesPanel handling and alignmentPlan for drawings and access
Barrier safetyCheck spacing and deflectionCheck glass and supportsMeet project requirements
Installation and adjustment

Step-by-step installation and tension adjustment

Each project begins with laser surveying and ends with individual cable tension adjustment using a tension meter.

01
Step

Laser surveying and post layout

Set out main and intermediate posts using approved drawings, post stiffness and permitted cable deflection. Check the floor and structural edge before fabrication.

02
Step

Mechanical anchoring of base plates

Select and verify anchor type, embedment, edge distance and concrete or steel connections against the supporting structure and technical documentation.

03
Step

Cable threading and hydraulic terminal attachment

Pass grade 316 cables through insulating bushings and attach end pins using a calibrated workshop press.

04
Step

Dynamic adjustment with a tension gauge

Set and record each cable’s tension according to manufacturer instructions and system design. After checking anchors and fittings, provide the client with inspection and maintenance requirements.

Pricing factors

Factors determining cable railing cost per linear metre

Cable railing cost depends on cable grade and diameter, fitting quantities, run length, supporting works and installation method. Compare the component list, labour and installation conditions alongside the price.

Final pricing is confirmed after reviewing drawings, length and fitting specifications.

Number of cable rows and arrangement

Cable count and direction, barrier height and infill spacing must follow the project design and applicable requirements. Terminal count, cable length and anchorage complexity affect the final cost.

Example arrangement
8 parallel rows

Post material and structural design

Select post material, section, thickness and finish for site exposure and loads. Tubular, box-section and flat-bar posts each require suitable fabrication and connection details.

Surface finish
Matt, polished or gold PVD

Fittings and fabrication choices

Tensioners must match cable construction, installation space, adjustment range and service access. Compare concealed and exposed fittings by technical documents, fabrication quality and maintainability.

Manufacturing technology
CNC Monoblock
Applications and projects

Selected completed Aris Nardeh projects

Explore recent cable railing installations in contemporary Lavasan villas and Zaferaniyeh penthouses in Tehran.

Cable railing on an open-view villa terrace
Mountain villa, Asalak, Lavasan

65 linear metres of terrace cable railing with a 180-degree view

Custom grade 316 stainless flat-bar posts with ten rows of 5 mm wire rope and tensioners concealed inside the balustrade profile.

Length: 65 linear metres
•
Tension: 120 kgf
•
Completed: summer 1403 SH
Cable railing on an architectural staircase
Zaferaniyeh penthouse, Tehran

Floating spiral stair with matt grade 316 cable railing

38 mm stainless tube handrail and 6 mm wire rope without obstructive intermediate posts.

Cable railing in an outdoor architectural setting
Fereshteh residential tower roof garden

Infinity pool perimeter balustrade

Select stainless grade and finish, rinsing requirements and fitting access for the pool area’s moisture and actual exposure.

Technical questions answered

Questions from clients and site supervisors

Engineering answers to common technical questions about tension cable systems.

Project assessment request

Online price enquiry and site assessment request

Share initial specifications, approximate length and project location so we can review feasibility, site-visit needs and quotation items. Response timing and final terms are confirmed after reviewing your information.

Draft DWG connection details
Material authenticity according to order documentation
Site visits and laser measurement in Tehran and surrounding areas
Direct contact
+989125986609

When is cable railing suitable?

Cable railing combines tensioned cables, posts and end fittings. Suitability depends on the supporting structure, post spacing, tension control and local safety requirements. Where children have access, the climbability of cable infill must be considered during design and code review.