Skip to content
Project consultation and site visits across Iran
Safety requirements and connection details
STRUCTURAL GLASS BALUSTRADE SYSTEMS

Engineered glass railing Design, installation and price enquiries

Design and installation of base-shoe, spigot, point-fixed and surface-mounted glass railings for terraces, stairs and pool areas. Glass, fittings and supporting structure are selected for each project. Send a drawing or approximate length to compare systems and request a quotation.

Project requirements review
Height and installation details
Lateral load design
Based on each project's conditions
Grade 316 stainless steel
Oxidation and salt resistance
Glass railing on a terrace with an open view
SPECIFICATION SPEC-A1

Aris internal recessed system

21.52 mm low-iron laminated glass

LAMINATED STRUCTURAL GLASS
Safety factor: 4.5
10 mm tempered glass PVB 1.52mm 10 mm tempered glass Total: 21.52 mm Super Clear Lateral wind load
LIGHT TRANSMISSION
91.8% light transmission
IRON CONTENT
Low-iron glass: stated below 100 PPM
Engineering and material design

How is the stability of Aris glass railings achieved?

In balustrade engineering, each glass panel acts as a structural barrier rather than decoration alone, resisting impact and storm loads. We use double-layer tempered laminated glass, including 10+10 and 8+8 configurations, with PVB or SentryGlas interlayers from established international manufacturers.

Low-iron clarity

Ordinary float glass has a green tint. Aris specifies high-clarity low-iron glass to preserve views and facade colours.

Post-breakage performance

If both glass layers break following a severe impact, the PVB interlayer retains the fragments within the frame to help limit glass fallout and protect occupants.

ARCHITECTURAL SYSTEM CONFIGURATIONS

Four Aris glass railing systems

Systems selected by supporting structure, architectural sightlines and required lateral loads

Example of a base-shoe glass railing system
IN-GROUND FLUSH
Recessed / concealed system

Recessed base-shoe system

Heavy-duty aluminium profiles are recessed into the concrete slab or floor build-up, leaving a clean glass plane rising from the floor without visible supporting elements.

Recommended thickness:
10+10 and 12+12 mm
Ideal application:
Penthouse terraces and roof gardens
Example of a spigot glass railing system
STAND-ALONE CLAMP
Self-supporting post system

Spigot system

Solid cast grade 316 stainless steel spigots grip the glass without drilling. Suitable for pool surrounds and courtyards where drainage and surface cleaning are priorities.

Material alloy:
Stainless Steel 316
Ideal application:
Pool surrounds and courtyards
Example of a point-fixed glass railing system
SIDE FASCIA MOUNT
Fascia-mounted system

Point-fixing system

50 mm diameter grade 316 stainless steel point fixings attach directly to the fascia of slabs and stairs, preserving the usable floor width of balconies and corridors.

Space saving:
Reduced floor occupation, subject to side-fixing details
Ideal application:
Floating stairs and commercial atriums
Example of a surface-mounted glass railing system
SURFACE EXPOSED
Surface-mounted exposed system

Exposed U-channel system

Surface mounting requires checks of the profile, anchors, waterproofing and compatibility with the finished floor. Installation without demolition depends on the actual supporting structure and access to anchor points.

Installation speed:
Fast installation method
Ideal application:
New-build terraces, hotels and lobbies
METALLURGY & TECHNICAL COMPARISON

Technical specifications, metallurgy and load standards

Material engineering specifications and physical testing standards with reference to Iran’s Road, Housing and Urban Development Research Center guidance

System typeGlass type and thicknessFitting metallurgyLateral loads and design documentationFire safety approvalExample height; subject to design
Recessed base shoe10+10 or 12+12 low-iron laminated glassHardened extruded 6063-T6 aluminiumAccording to system calculations and documentation Subject to project review and approval110–140 cm
Self-supporting spigots8+8 or 10+10 tempered laminated glass with 1.52 mm PVBSolid precision-cast 316 stainless steelAccording to system calculations and documentation Subject to project review and approval90–110 cm
Point-fixing system10+10 and 12+12 laminated glass with SentryGlasCNC-machined 316L acid-resistant stainless steel componentsAccording to system calculations and documentation Subject to project review and approval110–130 cm
Surface-mounted exposed U-channel8+8 and 10+10 grade-A tempered laminated glassAluminium profile with a 20-micron anodised coatingAccording to system calculations and documentation Subject to project review and approval100–120 cm

The table supports an initial comparison of systems and does not represent final specifications or general approval. Glass thickness, height, anchors and supporting structure must be determined from panel dimensions, design loads, local requirements and the project designer's assessment.

Technical reference for glazing in railing systems: ASTM E2358-24

TRANSPARENT PRICING METRICS

Factors affecting current glass railing prices

Final cost depends on linear length, structural load specifications and connection profiles. Aris aims to provide clear itemised engineering quotations without hidden costs, with material authenticity documented for steel and glass.

Specialist advice for an efficient estimate

Compare options with clear technical specifications to assess material, installation and maintenance costs. Changes to thickness or connections require the designer’s approval and supporting calculations.

1. Length and geometry

Larger project quantities can reduce the unit cost per linear metre by optimising glass cutting and reducing interlayer waste.

2. Glass thickness and laminated configuration

Choosing 8+8, 10+10 or 12+12 glass with acoustic or SentryGlas interlayers directly affects the final budget.

3. Structural connection type

Recessed systems require supporting frames and floor preparation, while 316 stainless point fixings depend on the balcony fascia dimensions.

4. Floor height and wind exposure

Storey height, location and wind exposure affect design loads and the selection of glass, profiles and connections. Final values must be established by the project calculations.

SYSTEMATIC METHODOLOGY

Six stages of engineering and installation at Aris Nardeh

From concept to final handover under the supervision of materials engineers and building engineering inspectors

01

Consultation and load assessment

Review facade wind exposure, calculate imposed loads and propose a system suited to municipal requirements.

02

3D laser surveying

Survey elevations and out-of-plumb beams using total stations and digital laser distance meters.

03

Engineering shop drawings

Prepare detailed CAD fabrication drawings, including joint spacing and bolt positions.

04

Glass production and fitting machining

Glass tempering and lamination with imported interlayers, and CNC machining of stainless steel fittings at the Aris factory.

05

Installation by trained technicians

Laser alignment of glass using wedges and specified Fischer anchors, followed by construction silicone sealing.

06

Load testing and final handover

Check installation specifications, alignment and connections; carry out the tests agreed in the contract and hand over maintenance instructions and written warranty conditions.

FREQUENTLY ASKED QUESTIONS

Glass railing frequently asked questions

Aris Nardeh specialists answer questions about approvals, safety and maintenance

CALCULATE & DIRECT ESTIMATION

Online glass railing price and length enquiry

Enter your initial project details. The stated service includes a preliminary engineering quotation, shop drawing details and a fitting catalogue within two working hours.

Contact the sales engineering manager:
Send drawings and files via WhatsApp / Eitaa:

What determines glass railing safety?

Glass railing safety depends on the combined design of the glass, fittings, anchors and supporting structure. Glass type and thickness must suit panel dimensions, location, design loads and post-breakage behaviour. Toughened or laminated glass alone does not replace proper engineering and installation.